Product Overview
Ruby3A from Kyland is specially designed for reliable industrial networking realizing both PRP (Parallel Redundancy Protocol) and HSR (High-availability Seamless Redundancy) which are defined in IEC62439-3. The Ruby3A provides the ultimate in network reliability and zero failover time from network faults. Full FPGA hardware solution enables Kyland Ruby3A low switching latency and PRP/HSR is selectable via software with the same hardware platform. Precision time synchronization in accordance with IEEE 1588v2 is supported on Kyland Ruby3A.
Key Features
- Compliant implementation of both PRP (IEC62439-3-4) and HSR (IEC62439-3-5)
- Supports combo ports as HSR/PRP port
- Supports hardware based IEEE1588v2
- Supports reset button for system reboot
- Out of Band Management Port
- Complies with IEC61850-3 and IEEE1613
Specifications
Software functions | Redundancy protocol | Support HSR and the recovery time is 0 ms Support PRP and the recovery time is 0 ms Support PRP/HSR Coupling Support Quadbox mode |
---|---|---|
Management and maintenance | Support Console and Web management Support Telnet Support CLI Support SNMPv1/v2c Support SNMPv3 Support LLDP Support DHCP client Support software update Support configuration download Support configuration upload Support FTP Support Syslog Support Alarm Support Cable test Support Port speed auto-negotiation Support IEC61850 MMS server | |
Time synchronization | Support PTPv2(IEEE1588-2008) transparent precision<1us Support NTP server/client Support SNTP | |
Security | Support SSH Support SFTP Support HTTPs/SSL Support Radius/Tacacs+ Support AAA, Line | |
Standard | IEEE 802.3ab(1000Base-T) IEEE 802.3z(1000Base-SX/LX) IEEE 802.3u(100Base-TX和100Base-FX) IEC62439-3-5(HSR, Edition 3.0 update ready) IEC62439-3-4(PRP, Edition 3.0 update ready) | |
Product Specifications | Interface | Gigabit ports: 1000Base-X, 100Base-FX, SFP port 100/1000Base-T(X), RJ45 port Console port:RS232,RJ45 Alarm contact: 3-pin 5.08mm-spacing plug-in terminal block, 250 VAC/220 VDC Max, 2 A Max, 60 W Max |
LED | LED on front panel: Running LED: Run Alarm LED: Alarm Power LED: PWR1, PWR2 Local port link LED: L HSR/PRP mode LED:Mode Port LED:Link/ACT | |
Button | Reset: supports system reboot | |
Power Requirements | Power input: 24-48VDC(18-72VDC), 100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) Power terminal: 5-pin 5.08 mm-spacing plug-in terminal block(L2/HV-HV) 3-pin 7.62 mm-spacing plug-in terminal block(HV) Power consumption:<8W Overload protection:Support Reverse connection protection:Support Redundancy protection:Support | |
Physical Characteristics | Housing:Metal Cooling:Natural cooling, fanless Protection Class:IP40 Dimensions(WxHxD):66×135×107.5 mm; 88 x 137 x 135 mm(HV-HV) Weight:1.25Kg Mounting:Din-rail or panel mounting | |
Environmental limits | Operating temperature: -40°C to +85°C Storage temperature: -40°C to +85°C Ambient Relative Humidity: 5% - 95% (non-condensing) | |
Quality assurance | MTBF:351889h Warranty:5 years | |
Approvals | CE, FCC EMC: EN 55032/35, EN 61000-6-4, EN 61000-6-2 Rail Traffic: EN 50121-4 IEC61850-3, IEEE1613 IEC 62368-1, EN 62368-1 | |
Industry standard | EMI:FCC CFR47 Part 15,EN55022/CISPR22,Class A EMS: IEC61000-4-2(ESD) ±8kV(contact),±15kV(air) IEC61000-4-3(RS) 10V/m(80MHz-2GHz) IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV IEC61000-4-5(Surge) Power Port:±2kV/DM,±4kV/CM;Data Port:±2kV IEC61000-4-6(CS) 3V(10kHz-150kHz);10V(150kHz-80MHz) IEC61000-4-16(common mode conduction) 30V(cont.),300V(1s) Machinery: IEC60068-2-6 (vibration) IEC60068-2-27 (shock) IEC60068-2-32 (free fall) |
Mechanical Drawing
Ordering Information
Product Model | Description |
---|---|
Ruby3A-3G-HV | 3x1000Base-X, 100Base-X, 100/1000Base-T(X) Combo ports; 100-240VAC,50/60Hz; 110-220VDC(85-264VAC/77-300VDC), single power input |
Ruby3A-3G-HV-HV | 3x1000Base-X, 100Base-X, 100/1000Base-T(X) Combo ports; 100-240VAC,50/60Hz; 110-220VDC(85-264VAC/77-300VDC), redundant power inputs |
Ruby3A-3G-L2-L2 | 3x1000Base-X, 100Base-X, 100/1000Base-T(X) Combo ports; 24-48VDC(18-72VDC), redundant power inputs |
Downloads
Name | Type | File Size | |
---|---|---|---|
SS_IEC 61850 Substation Implementation_PEA_Thailand | Success Stories | ||
Ruby3A_Industrial-Ethernet-Switches-Hardware-Installation-Manual_V1.0 | Hardware Installation Manual | ||
Ruby3A-Series_PRP-HSR-Switches-Web-Operation-Manual_V1.1 | Operation Manual | ||
SS_Duyen Hai 220KV Substation_TCA_Vietnam | Success Stories | ||
Kyland_Ruby3A_Datasheet | Datasheet |
Number of Ports | 0 – 8 |
---|---|
Certificate | CE/FCC, EN50121-4, IEC61850-3/IEEE1613 |
Installation | DIN Rail Ethernet Switches |
Network Interface | Fiber Connectors, RJ45 Connectors |
Interface | Full Gigabit |
Power Supply | 24-48V DC, 220V AC |
Operation Temperature | -40°C ~ 85°C |
Unmanaged/managed | Layer 2 Managed Switches |
IP Class | IP40 |
Redundancy | HSR/PRP |