Product Overview

Ruby3A from Kyland is specially designed for reliable industrial networking realizing both PRP (Parallel Redundancy Protocol) and HSR (High-availability Seamless Redundancy) which are defined in IEC62439-3. The Ruby3A provides the ultimate in network reliability and zero failover time from network faults. Full FPGA hardware solution enables Kyland Ruby3A low switching latency and PRP/HSR is selectable via software with the same hardware platform. Precision time synchronization in accordance with IEEE 1588v2 is supported on Kyland Ruby3A. 

Key Features
  • Compliant implementation of both PRP (IEC62439-3-4) and HSR (IEC62439-3-5)
  • Supports combo ports as HSR/PRP port
  • Supports hardware based IEEE1588v2
  • Supports reset button for system reboot
  • Out of Band Management Port
  • Complies with IEC61850-3 and IEEE1613
Specifications
Software functionsRedundancy protocolSupport HSR and the recovery time is 0 ms
Support PRP and the recovery time is 0 ms
Support PRP/HSR Coupling
Support Quadbox mode
Management and maintenanceSupport Console and Web management
Support Telnet
Support CLI
Support SNMPv1/v2c
Support SNMPv3
Support LLDP
Support DHCP client
Support software update
Support configuration download
Support configuration upload
Support FTP
Support Syslog
Support Alarm
Support Cable test
Support Port speed auto-negotiation
Support IEC61850 MMS server
Time synchronizationSupport PTPv2(IEEE1588-2008) transparent precision<1us
Support NTP server/client
Support SNTP
SecuritySupport SSH
Support SFTP
Support HTTPs/SSL
Support Radius/Tacacs+
Support AAA, Line
StandardIEEE 802.3ab(1000Base-T)
IEEE 802.3z(1000Base-SX/LX)
IEEE 802.3u(100Base-TX和100Base-FX)
IEC62439-3-5(HSR, Edition 3.0 update ready)
IEC62439-3-4(PRP, Edition 3.0 update ready)
Product SpecificationsInterfaceGigabit ports:
1000Base-X, 100Base-FX, SFP port
100/1000Base-T(X), RJ45 port
Console port:RS232,RJ45
Alarm contact:
3-pin 5.08mm-spacing plug-in terminal block, 250 VAC/220 VDC Max, 2 A Max, 60 W Max
LEDLED on front panel:
Running LED: Run
Alarm LED: Alarm
Power LED: PWR1, PWR2
Local port link LED: L
HSR/PRP mode LED:Mode
Port LED:Link/ACT
ButtonReset: supports system reboot
Power RequirementsPower input:
24-48VDC(18-72VDC),
100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)
Power terminal:
5-pin 5.08 mm-spacing plug-in terminal block(L2/HV-HV)
3-pin 7.62 mm-spacing plug-in terminal block(HV)
Power consumption:<8W
Overload protection:Support
Reverse connection protection:Support
Redundancy protection:Support
Physical CharacteristicsHousing:Metal
Cooling:Natural cooling, fanless
Protection Class:IP40
Dimensions(WxHxD):66×135×107.5 mm; 88 x 137 x 135 mm(HV-HV)
Weight:1.25Kg
Mounting:Din-rail or panel mounting
Environmental limitsOperating temperature: -40°C to +85°C
Storage temperature: -40°C to +85°C
Ambient Relative Humidity: 5% - 95% (non-condensing)
Quality assuranceMTBF:351889h
Warranty:5 years
ApprovalsCE, FCC
EMC: EN 55032/35, EN 61000-6-4, EN 61000-6-2
Rail Traffic: EN 50121-4
IEC61850-3, IEEE1613
IEC 62368-1, EN 62368-1
Industry standardEMI:FCC CFR47 Part 15,EN55022/CISPR22,Class A
EMS:
IEC61000-4-2(ESD) ±8kV(contact),±15kV(air)
IEC61000-4-3(RS) 10V/m(80MHz-2GHz)
IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV
IEC61000-4-5(Surge) Power Port:±2kV/DM,±4kV/CM;Data Port:±2kV
IEC61000-4-6(CS) 3V(10kHz-150kHz);10V(150kHz-80MHz)
IEC61000-4-16(common mode conduction) 30V(cont.),300V(1s)
Machinery:
IEC60068-2-6 (vibration)
IEC60068-2-27 (shock)
IEC60068-2-32 (free fall)
Mechanical Drawing
Ordering Information
Product ModelDescription
Ruby3A-3G-HV3x1000Base-X, 100Base-X, 100/1000Base-T(X) Combo ports; 100-240VAC,50/60Hz; 110-220VDC(85-264VAC/77-300VDC), single power input
Ruby3A-3G-HV-HV3x1000Base-X, 100Base-X, 100/1000Base-T(X) Combo ports; 100-240VAC,50/60Hz; 110-220VDC(85-264VAC/77-300VDC), redundant power inputs
Ruby3A-3G-L2-L23x1000Base-X, 100Base-X, 100/1000Base-T(X) Combo ports; 24-48VDC(18-72VDC), redundant power inputs
Downloads
NameTypeFile Size
SS_IEC 61850 Substation Implementation_PEA_Thailand
Success Stories
Download
Ruby3A_Industrial-Ethernet-Switches-Hardware-Installation-Manual_V1.0
Hardware Installation Manual
Download
Ruby3A-Series_PRP-HSR-Switches-Web-Operation-Manual_V1.1
Operation Manual
Download
SS_Duyen Hai 220KV Substation_TCA_Vietnam
Success Stories
Download
Kyland_Ruby3A_Datasheet
Datasheet
Download
Number of Ports

0 – 8

Certificate

CE/FCC, EN50121-4, IEC61850-3/IEEE1613

Installation

DIN Rail Ethernet Switches

Network Interface

Fiber Connectors, RJ45 Connectors

Interface

Full Gigabit

Power Supply

24-48V DC, 220V AC

Operation Temperature

-40°C ~ 85°C

Unmanaged/managed

Layer 2 Managed Switches

IP Class

IP40

Redundancy

HSR/PRP

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • CPU
  • pa_height
  • Memory
  • Storage
  • Unmanaged/managed
  • Installation
  • Operation Temperature
  • Interface
  • Network Interface
  • Number of Ports
  • Power Supply
  • Certificate
  • Connectors
  • CPU
  • Display Port
  • Expansion
  • Features
  • Highlight Functions
  • I/O
  • IP Class
  • Memory
  • Port Numbers
  • Redundancy
  • Serial Port
  • Storage
  • USB
Compare