INTRODUCTION

IEC 61850, the global standard for communication in substations, is bringing open, Interoperable, systems, and flexible architectures, to the substation automation domain. Today's power utilities operate more globally and require flexible, future-proof systems to cope with changing requirements, philosophies, and technologies.

SPECIFICATIONS

System Requirements

  • IEC61850-3 Industrial Ethernet Switch
  • Intelligent Gateway for IED integration
  • Precise Time Synchronization Soltuion
BENEFITS

Why KLG Smartec

IEC61850-3 Industrial Ethernet Switch

  • Wide product range: Modularly designed rack mount switches and DIN-Rail models with high voltage input
  • Compliant with IEC61850-3 and IEEE 1613
  • Supports NTP, precise time sync IEEE1588v2 and ITU-T.G.8261/G.8262 (Sync-E)
  • Supports redundancy protocols: IEC62439-3(HSR/PRP), IEC62439-6(DRP), DT-Ring family, RSTP
  • Multi-service platform for switches and time server with GPS and IRIG-B modules
  • Built-in IEC61850 data modeling with MMS server for device management
  • Supports legacy RS232/485/422 serial connections combined with data switching

Intelligent Gateway for IED integration

  • Supports data collection from both legacy IEDs and IEC61850 IEDs with ethernet and serial connections
  • Easy configuration by importing standard .CID files
  • Supports protocols: IEC60870-5-101, IEC60870-5-102 (master), IEC60870-5-103 (master - slave), IEC60807-5-104 (master - slave), MODBUS (master -slave -
  • RTU/TCP), DNP 3.0 (master - slave - serial/over TCP/IP), SEL (master -fast meter/SER), AREVA (master - courier)
  • Supports BRCB and URCB reports, GOOSE messaging, MMS file transmissions and IEC61850 modules


Precise Time Synchronization Soltuion

  • Product portfolio includes time server, IEEE1588v2 Switch, clock converter, time test instrument
  • High precision time server with 100ns accuracy with multiple reference satellite systems: GPS, BD, GLONASS
  • Supports multiple reference source switchover within 200ns
  • Different oscillator options support holdover performance up to 1us/1h
  • IEEE1588 to IRIG-B conversion device for backward compatibility
  • Reliable multiple source selection algorithm and holdover performance
  • Optional management protocols of MMS/IEC60870-5-104/SNMP for time server
  • Compliant with IEEE PC 37.238 Power Profile